NEW QUESTION 14
The principle of the ( ) humidifier is that the high infrared light makes the water surface release water vapor and diffuse into the airflow that needs to be humidified.
- A. High pressure spray
- B. Infrared
- C. Humidity
- D. Electrodes
Answer: B
NEW QUESTION 15
The ECC800 is the core component of local management of the micro-module, and the access of its southbound components can be extended through the POE bus.
- A. False
- B. True
Answer: B
NEW QUESTION 16
FusionModule800 3.0 closed channel hot and cold channels are optional.
- A. False
- B. True
Answer: B
NEW QUESTION 17
Fusion Module2000 is an outdoor prefabricated integrated data center solution.
- A. True
- B. False
Answer: B
NEW QUESTION 18
The adjustable range of the number of cells in a single group of batteries supported by UPS5000S is?
- A. Sections 30 to 44
- B. Sections 30 to 48
- C. Sections 30 to 46
- D. Sections 30 to 42
Answer: B
NEW QUESTION 19
If the UPS5000-400K cuts the bypass and closes the maintenance side station, both the main power module and the bypass module stop working.
- A. FALSE
- B. TRUE
Answer: A
NEW QUESTION 20
When creating a camera in NETECO, in addition to obtaining the IP address of the camera, you also need to obtain ().
- A. Camera Encoding
- B. Camera Height
- C. Camera pixels
- D. Camera installation location
Answer: A
NEW QUESTION 21
Modifying the micro-module layout view on ECC800 supports simultaneous editing by ( ) users.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION 22
What is the maximum power of the IT cabinet of FusionModule500 & FusionModule800?
- A. 3KVA
- B. 5KVA
- C. 7KVA
- D. 9KVA
Answer: C
NEW QUESTION 23
If a project needs a management system to monitor the PUE value of the room, what function does NetEco need to quote separately?
- A. Capacity Management
- B. Mobile APP
- C. Energy Efficiency Management
- D. No separate quotation is required
Answer: C
NEW QUESTION 24
UPS5000-S-400K adopts () KVA power module.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION 25
When selecting to support only temperature detection and not to support hot-plug configuration, the switches in the slot must be fully configured.
- A. False
- B. True
Answer: B
NEW QUESTION 26
When UPS2000-G-(6-20KVA) is in ECO mode, the battery indicator and bypass indicator are on at the same time.
- A. True
- B. False
Answer: B
NEW QUESTION 27
The NetEco6000 management system can provide monitoring of the cooling power system, which of the following functions can it provide? (Multiple choice)
- A. None of the above is supported
- B. It can provide the topological diagram of the chilled water system, showing the operation status of the whole system
- C. The power distribution system topology diagram can be provided, and the power distribution system diagram of the entire computer room can be displayed
- D. Support the display of key equipment indicators on the power distribution topology diagram, so that users can understand the operating status of the system and important nodes
Answer: B,C,D
NEW QUESTION 28
UPS5000- has the function of adjustable number of battery cells, which can avoid the replacement of gangs caused by single battery failure, and solve the problem of difficult maintenance of traditional UPS batteries. How many adjustable batteries does UPS5000-E (50kVA module) support?
- A. 30-46
- B. 30-40
- C. 32-47
- D. 32-40
Answer: A
NEW QUESTION 29
What is the lightning protection level of the integrated UPS of FusionModule2000?
- A. C-level lightning protection
- B. A-level lightning protection
- C. B-level lightning protection
Answer: A
NEW QUESTION 30
UPS5000-E can maintain high efficiency in a wide load range and effectively reduce losses. Among them, the efficiency can reach 96% at 40% load, and the efficiency can reach 95% at 20% load. What is the efficiency in ECO mode?
- A. 97%
- B. 96%
- C. 98%
- D. 99%
Answer: D
NEW QUESTION 31
In NETECO's report management, which of the following types does periodic tasks have? (Multiple choice)
- A. Weekly report
- B. Monthly report
- C. The Daily
- D. The Times
Answer: A,B,C,D
NEW QUESTION 32
Configure the cables of the UPS. The total current carrying capacity of the cables is greater than the rated current of the UPS to meet the requirements of the project.
- A. False
- B. True
Answer: B
NEW QUESTION 33
Which of the following statements about the reliability of UPS5000-A (30kVA~120kVA) are correct? (Multiple choice)
- A. Inverter overload capacity is strong
- B. Three anti-paint coating technology
- C. Ultra-wide input voltage range
- D. 6kV/5kA lightning protection design
Answer: A,B,C,D
NEW QUESTION 34
The NetEco management system supports dispatching corresponding work orders for a certain alarm to track the entire processing process. What type of work order is this?
- A. Change Work Order
- B. Asset Work Order
- C. Alert Work Order
- D. Business Work Order
Answer: C
NEW QUESTION 35
When the battery is discharged, the discharge voltage of a faulty battery drops rapidly, and the backup time of the entire battery rented in the morning is not enough, so it should be dealt with ().
- A. No processing required
- B. Scrap the entire battery pack
- C. Force equal charge, replace the faulty battery
- D. to discharge
Answer: C
NEW QUESTION 36
When UPS5000-E shares a battery pack, the battery capacity parameter of each UPS is set to the total capacity of the entire battery pack.
- A. FALSE
- B. TRUE
Answer: B
NEW QUESTION 37
......