Pass DES-1221 Exam in First Attempt Guaranteed 2021 Dumps! [Q33-Q54]

Share

Pass DES-1221 Exam in First Attempt Guaranteed 2021 Dumps!

DES-1221 Dumps Full Questions - Exam Study Guide


Understanding functional and technical aspects of Specialist – Implementation Engineer, PowerStore Solutions Version 1.0 PowerStore Migration (15%)

The following will be discussed in DELL DES-1221 dumps:

  • Perform migration operations
  • Identify the PowerStore Migration requirements and capabilities
  • Describe the PowerStore Migration feature and process
  • Configure the migration requirements and capabilities
  • Configure the migration feature to import data from supported sources

 

NEW QUESTION 33
What is the recommended Windows multi-pathing policy for block volumes on a PowerStore array?

  • A. FailOver
  • B. Least QueueDepth
  • C. Round-Robin
  • D. Least Weighted Paths

Answer: C

 

NEW QUESTION 34
Refer to the Exhibit.

Which port location in the graphic is used for network management connectivity on a PowerStore T?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 35
What is the significance of the warning given when a volume with data services is deleted?

  • A. Snapshot is present on the volume
  • B. Volume is mapped to a host
  • C. Protection policy is configured on the volume
  • D. Volume is participating in a migration

Answer: D

Explanation:
Explanation/Reference: https://www.dell.com/support/manuals/en-pk/powerstore/pwrstr-cfg-vols/delete-a-volume?
guid=guid-26e8c12d-a3df-4d4d-8012-ae2ef9e53721&lang=en-us

 

NEW QUESTION 36
A customer is new to PowerStore and asks if there are any differences between the A and B back-end ports.
What is the correct response?

  • A. "A" ports are output ports and "B" ports are input ports
  • B. "A" ports are input ports and "B" ports are output ports
  • C. All ports on the base enclosure are output ports
  • D. All ports on the base enclosure are input ports

Answer: B

 

NEW QUESTION 37
What does a Storage Administrator need to consider about Resource Balance when assigning volumes?

  • A. Whether the Node is offline
    Appliance failure status
    Node utilization
  • B. Whether the appliance is online
    Appliance failure status
    Cluster utilization
  • C. Whether the Cluster is offline
    Node failure status
    I/O utilization
  • D. Whether the appliance is offline
    Appliance failure status
    Capacity utilization

Answer: D

 

NEW QUESTION 38
How is the upgrade process on a multi-appliance cluster run?

  • A. Master appliance primary node first, then the peer node
  • B. On one node at a time
  • C. On all primary nodes first, then peer nodes
  • D. In parallel on all nodes

Answer: A

 

NEW QUESTION 39
1.a.1 What is the maximum number of appliances that can be connected to form a cluster?

  • A. 4 in a PowerStore T cluster, 1 in a PowerStore X cluster
  • B. 4 in a PowerStore T cluster, 4 in a PowerStore X cluster
  • C. 1 in a PowerStore T cluster, 1 in a PowerStore X cluster
  • D. 1 in a PowerStore T cluster, 4 in a PowerStore X cluster

Answer: B

 

NEW QUESTION 40
What does a Storage Administrator need to consider about Resource Balance when assigning volumes?

  • A. Whether the appliance is online Appliance failure status
    Cluster utilization
  • B. Whether the appliance is offline Appliance failure status Capacity utilization
  • C. Whether the Node is offline Appliance failure status Node utilization
  • D. Whether the Cluster is offline Node failure status
    I/O utilization

Answer: B

 

NEW QUESTION 41
What is the correct power up sequence for a PowerStore?

  • A. 1. Base Enclosure Node B, 2. Base Enclosure Node A, 3. Expansion Enclosure
  • B. 1. Expansion Enclosure, 2. Base Enclosure
  • C. 1. Base Enclosure Node A, 2. Base Enclosure Node B, 3. Expansion Enclosure
  • D. 1. Base Enclosure, 2. Expansion Enclosure

Answer: B

Explanation:
Reference: https://www.dell.com/support/manuals/en-pk/powerstore/pwrstr-pwdwn-reboot/power-on-a- powerstore-t-model-appliance?guid=guid-1a60464d-b2e6-45bf-86a1-d5ab5f716361&lang=en-us

 

NEW QUESTION 42
Use the PowerStore Manager simulator to configure the BaseEnclosure-NodeA-IoModule1-FEport0 as a replication port. When you have finished using the simulator, Click Next.

Answer:

Explanation:
Below are the exhibits solution for this simulation.








 

NEW QUESTION 43
Match the correct Base Enclosure port in column A to the Expansion Enclosure port in column B to show the correct cabling for adding a single expansion enclosure to a base enclosure.

Answer:

Explanation:

 

NEW QUESTION 44
A storage administrator has provisioned 10*2GB volumes. 400MB of data is written to each of the ten volumes. What is the Thin Savings ratio for this configuration?

  • A. 3:1
  • B. 6:1
  • C. 4:1
  • D. 5:1

Answer: B

 

NEW QUESTION 45
What does the data import session Pause operation do?

  • A. Deactivates the host to PowerStore data path
  • B. Stops the source to PowerStore background copy operation
  • C. Stops the source to PowerStore cutover operation
  • D. Deactivates the host to PowerStore control path

Answer: B

 

NEW QUESTION 46
What describes the Import External Storage feature?

  • A. A native data migration feature of PowerStore that imports external block storage to PowerStore
  • B. An external plugin feature for hosts to tune application workload IO on PowerStore NVMe based storage
  • C. A native network configuration feature of PowerStore that configures external Ethernet switching for PowerStore installation
  • D. A feature external to PowerStore that orchestrates vMotion movement of virtual machines onto PowerStore X systems

Answer: A

Explanation:
Reference: https://www.dell.com/support/manuals/en-pk/powerstore-1000/pwrstr-import/importing-external- storage-to-powerstore-overview?guid=guid-6fef77c4-d4c9-49c6-8de2-efd67aa52ca5

 

NEW QUESTION 47
A PowerStore X system is being implemented using Dell EMC S5248F-ON Ethernet switching as data switches.
What is required when configuring the VLT interconnects on the data switches?

  • A. Set the VLT connection to the switch default VLAN
  • B. On each switch, select the switch management port MAC as the VLT MAC
  • C. Assign the switch default route for the VLT traffic
  • D. Configure the VLT MACs with a matching unique made-up address

Answer: B

 

NEW QUESTION 48
Use the simulator to determine how many logical ports are currently marked for replication on the PowerStore appliance.
Note: It is necessary to close (x) the simulator window before you can select a response to this question.
Simulator:









  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 49
An administrator receives an alert on a PowerStore Cluster with three appliances:
The appliance A1 is projected to run out of space in 8 days
Capacity utilization is above 90 percent
Which tools are available to assist the Administrator with a potential resolution?

  • A. Thin provision conversion wizard
  • B. System Optimization
  • C. Assisted Migration
  • D. Space reclamation wizard

Answer: C

Explanation:
Explanation/Reference:
Reference: https://volumes.blog/2020/05/18/what-is-powerstore-part-11-resource-balancer/

 

NEW QUESTION 50
What is the recommended Windows multi-pathing policy for block volumes on a PowerStore array?

  • A. FailOver
  • B. Least QueueDepth
  • C. Round-Robin
  • D. Least Weighted Paths

Answer: C

Explanation:
Reference: https://www.delltechnologies.com/en-us/collaterals/unauth/technical-guides-support-information/ products/storage-2/docu5134.pdf

 

NEW QUESTION 51
What is the logical block size when creating and formatting volumes on PowerStore for Windows hosts?

  • A. 520 bytes
  • B. 512 bytes
  • C. 64 kilobytes
  • D. 4096 bytes

Answer: B

 

NEW QUESTION 52
Which administrator tasks are needed to increase the size of a VMFS datastore without the use of the VSI plugin, mounted to an external ESXi host?

  • A. Change the size of the datastore in vSphere and restart the VAAI service in PowerStore Manager
  • B. Change the volume size in PowerStore Manager and refresh the size of the datastore in vSphere
  • C. Change the size of the datastore in vSphere and refresh the size of the volume in PowerStore Manager
  • D. Change the volume size in PowerStore Manager and restart the VASA service in vSphere

Answer: B

Explanation:
Reference:
https://www.delltechnologies.com/en-us/collaterals/unauth/white-papers/products/storage/h18116- dell-emc-powerstore-vmware-vsphere-best-practices.pdf

 

NEW QUESTION 53
What is a requirement for the Import External Storage migration feature?

  • A. PowerPath host-based multipathing software
  • B. PowerStore Global Storage Discovery IP address must be configured
  • C. Direct Fibre Channel connections between storage systems
  • D. PowerStore LACP bonded ports are tagged for replication

Answer: B

 

NEW QUESTION 54
......


Understanding functional and technical aspects of Specialist – Implementation Engineer, PowerStore Solutions Version 1.0 PowerStore Configuration (22%)

The following will be discussed in DELL DES-1221 dumps:

  • Provision and configure block, file, and VMware storage
  • Describe and configure intercluster data migration
  • Configure host and client access to PowerStore block, file, and VMware storage
  • Describe and configure local and remote data protection on PowerStore storage resources

 

DCS-IE  Free Certification Exam Material from ExamBoosts with 62 Questions: https://www.examboosts.com/EMC/DES-1221-practice-exam-dumps.html

Use Real DES-1221 - 100% Cover Real Exam Questions: https://drive.google.com/open?id=17gri4kYVJ6ccQdBj658EsvxGwuWgLaJe