Pass DES-1221 Exam in First Attempt Guaranteed 2021 Dumps!
DES-1221 Dumps Full Questions - Exam Study Guide
Understanding functional and technical aspects of Specialist â Implementation Engineer, PowerStore Solutions Version 1.0 PowerStore Migration (15%)
The following will be discussed in DELL DES-1221 dumps:
- Perform migration operations
- Identify the PowerStore Migration requirements and capabilities
- Describe the PowerStore Migration feature and process
- Configure the migration requirements and capabilities
- Configure the migration feature to import data from supported sources
NEW QUESTION 33
What is the recommended Windows multi-pathing policy for block volumes on a PowerStore array?
- A. FailOver
- B. Least QueueDepth
- C. Round-Robin
- D. Least Weighted Paths
Answer: C
NEW QUESTION 34
Refer to the Exhibit.
Which port location in the graphic is used for network management connectivity on a PowerStore T?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION 35
What is the significance of the warning given when a volume with data services is deleted?
- A. Snapshot is present on the volume
- B. Volume is mapped to a host
- C. Protection policy is configured on the volume
- D. Volume is participating in a migration
Answer: D
Explanation:
Explanation/Reference: https://www.dell.com/support/manuals/en-pk/powerstore/pwrstr-cfg-vols/delete-a-volume?
guid=guid-26e8c12d-a3df-4d4d-8012-ae2ef9e53721&lang=en-us
NEW QUESTION 36
A customer is new to PowerStore and asks if there are any differences between the A and B back-end ports.
What is the correct response?
- A. "A" ports are output ports and "B" ports are input ports
- B. "A" ports are input ports and "B" ports are output ports
- C. All ports on the base enclosure are output ports
- D. All ports on the base enclosure are input ports
Answer: B
NEW QUESTION 37
What does a Storage Administrator need to consider about Resource Balance when assigning volumes?
- A. Whether the Node is offline
Appliance failure status
Node utilization - B. Whether the appliance is online
Appliance failure status
Cluster utilization - C. Whether the Cluster is offline
Node failure status
I/O utilization - D. Whether the appliance is offline
Appliance failure status
Capacity utilization
Answer: D
NEW QUESTION 38
How is the upgrade process on a multi-appliance cluster run?
- A. Master appliance primary node first, then the peer node
- B. On one node at a time
- C. On all primary nodes first, then peer nodes
- D. In parallel on all nodes
Answer: A
NEW QUESTION 39
1.a.1 What is the maximum number of appliances that can be connected to form a cluster?
- A. 4 in a PowerStore T cluster, 1 in a PowerStore X cluster
- B. 4 in a PowerStore T cluster, 4 in a PowerStore X cluster
- C. 1 in a PowerStore T cluster, 1 in a PowerStore X cluster
- D. 1 in a PowerStore T cluster, 4 in a PowerStore X cluster
Answer: B
NEW QUESTION 40
What does a Storage Administrator need to consider about Resource Balance when assigning volumes?
- A. Whether the appliance is online Appliance failure status
Cluster utilization - B. Whether the appliance is offline Appliance failure status Capacity utilization
- C. Whether the Node is offline Appliance failure status Node utilization
- D. Whether the Cluster is offline Node failure status
I/O utilization
Answer: B
NEW QUESTION 41
What is the correct power up sequence for a PowerStore?
- A. 1. Base Enclosure Node B, 2. Base Enclosure Node A, 3. Expansion Enclosure
- B. 1. Expansion Enclosure, 2. Base Enclosure
- C. 1. Base Enclosure Node A, 2. Base Enclosure Node B, 3. Expansion Enclosure
- D. 1. Base Enclosure, 2. Expansion Enclosure
Answer: B
Explanation:
Reference: https://www.dell.com/support/manuals/en-pk/powerstore/pwrstr-pwdwn-reboot/power-on-a- powerstore-t-model-appliance?guid=guid-1a60464d-b2e6-45bf-86a1-d5ab5f716361&lang=en-us
NEW QUESTION 42
Use the PowerStore Manager simulator to configure the BaseEnclosure-NodeA-IoModule1-FEport0 as a replication port. When you have finished using the simulator, Click Next.
Answer:
Explanation:
Below are the exhibits solution for this simulation.








NEW QUESTION 43
Match the correct Base Enclosure port in column A to the Expansion Enclosure port in column B to show the correct cabling for adding a single expansion enclosure to a base enclosure.
Answer:
Explanation:

NEW QUESTION 44
A storage administrator has provisioned 10*2GB volumes. 400MB of data is written to each of the ten volumes. What is the Thin Savings ratio for this configuration?
- A. 3:1
- B. 6:1
- C. 4:1
- D. 5:1
Answer: B
NEW QUESTION 45
What does the data import session Pause operation do?
- A. Deactivates the host to PowerStore data path
- B. Stops the source to PowerStore background copy operation
- C. Stops the source to PowerStore cutover operation
- D. Deactivates the host to PowerStore control path
Answer: B
NEW QUESTION 46
What describes the Import External Storage feature?
- A. A native data migration feature of PowerStore that imports external block storage to PowerStore
- B. An external plugin feature for hosts to tune application workload IO on PowerStore NVMe based storage
- C. A native network configuration feature of PowerStore that configures external Ethernet switching for PowerStore installation
- D. A feature external to PowerStore that orchestrates vMotion movement of virtual machines onto PowerStore X systems
Answer: A
Explanation:
Reference: https://www.dell.com/support/manuals/en-pk/powerstore-1000/pwrstr-import/importing-external- storage-to-powerstore-overview?guid=guid-6fef77c4-d4c9-49c6-8de2-efd67aa52ca5
NEW QUESTION 47
A PowerStore X system is being implemented using Dell EMC S5248F-ON Ethernet switching as data switches.
What is required when configuring the VLT interconnects on the data switches?
- A. Set the VLT connection to the switch default VLAN
- B. On each switch, select the switch management port MAC as the VLT MAC
- C. Assign the switch default route for the VLT traffic
- D. Configure the VLT MACs with a matching unique made-up address
Answer: B
NEW QUESTION 48
Use the simulator to determine how many logical ports are currently marked for replication on the PowerStore appliance.
Note: It is necessary to close (x) the simulator window before you can select a response to this question.
Simulator:









- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION 49
An administrator receives an alert on a PowerStore Cluster with three appliances:
The appliance A1 is projected to run out of space in 8 days
Capacity utilization is above 90 percent
Which tools are available to assist the Administrator with a potential resolution?
- A. Thin provision conversion wizard
- B. System Optimization
- C. Assisted Migration
- D. Space reclamation wizard
Answer: C
Explanation:
Explanation/Reference:
Reference: https://volumes.blog/2020/05/18/what-is-powerstore-part-11-resource-balancer/
NEW QUESTION 50
What is the recommended Windows multi-pathing policy for block volumes on a PowerStore array?
- A. FailOver
- B. Least QueueDepth
- C. Round-Robin
- D. Least Weighted Paths
Answer: C
Explanation:
Reference: https://www.delltechnologies.com/en-us/collaterals/unauth/technical-guides-support-information/ products/storage-2/docu5134.pdf
NEW QUESTION 51
What is the logical block size when creating and formatting volumes on PowerStore for Windows hosts?
- A. 520 bytes
- B. 512 bytes
- C. 64 kilobytes
- D. 4096 bytes
Answer: B
NEW QUESTION 52
Which administrator tasks are needed to increase the size of a VMFS datastore without the use of the VSI plugin, mounted to an external ESXi host?
- A. Change the size of the datastore in vSphere and restart the VAAI service in PowerStore Manager
- B. Change the volume size in PowerStore Manager and refresh the size of the datastore in vSphere
- C. Change the size of the datastore in vSphere and refresh the size of the volume in PowerStore Manager
- D. Change the volume size in PowerStore Manager and restart the VASA service in vSphere
Answer: B
Explanation:
Reference:
https://www.delltechnologies.com/en-us/collaterals/unauth/white-papers/products/storage/h18116- dell-emc-powerstore-vmware-vsphere-best-practices.pdf
NEW QUESTION 53
What is a requirement for the Import External Storage migration feature?
- A. PowerPath host-based multipathing software
- B. PowerStore Global Storage Discovery IP address must be configured
- C. Direct Fibre Channel connections between storage systems
- D. PowerStore LACP bonded ports are tagged for replication
Answer: B
NEW QUESTION 54
......
Understanding functional and technical aspects of Specialist â Implementation Engineer, PowerStore Solutions Version 1.0 PowerStore Configuration (22%)
The following will be discussed in DELL DES-1221 dumps:
- Provision and configure block, file, and VMware storage
- Describe and configure intercluster data migration
- Configure host and client access to PowerStore block, file, and VMware storage
- Describe and configure local and remote data protection on PowerStore storage resources
DCS-IE Free Certification Exam Material from ExamBoosts with 62 Questions: https://www.examboosts.com/EMC/DES-1221-practice-exam-dumps.html
Use Real DES-1221 - 100% Cover Real Exam Questions: https://drive.google.com/open?id=17gri4kYVJ6ccQdBj658EsvxGwuWgLaJe